Dalcnet ADC-1248-4CH enters the lamp field as follows;
Connection voltage; 12VDC - 52VDC
max. output current on each 0-10 V channel; 10 mA
max. output current on each relay output; 500 mA
The coil voltage of the auxiliary relay must be equal to the selected connection voltage of the appliance and must be equipped with an extinguishing diode.
A frequently asked question is about the 0-10V output. At 0% dimming value, this is 0 Volt. Many drivers, however, do not switch the LEDs off completely at 0 Volt and that is what the auxiliary output is for. With that contact (which is designed as a triac output) you can release a relay at 0% dimming value. The relay can in turn supply your drivers with 230V, whereby the coil voltage of the auxiliary relay is equal to the input voltage you selected. You could also choose to choose a solid state relay. We have various relays in our CASAMBI ACCESSORIES
The dimmer is set to 'DIM CONVERTER' by default. However, if you change the profile to '4CH DRIVER RELAY', the 0-10V outputs will be ignored and you can use the relay outputs as 'on-off'.
Dalcnet ADC-1248-4CH is delivered in a cardboard box;
Below is the PDF. PDF not displayed correctly? click here.